RED DRAGON WEED DRAGON TORCH KIT 500,000 BTU/hr with Squeeze Handle


RED DRAGON WEED DRAGON TORCH KIT 500,000 BTU/hr with Squeeze Handle

Looking for an alternative to pesticides? Burn the Weed with Flame Engineering’s, “Red Dragon” torch kit!

We are stocking the high-quality US brand Flame Engineering: RED DRAGON WEED BURNER TORCH KIT with Squeeze Handle

The WEED DRAGON® is the perfect propane torch kit for home and garden users who don’t want to rely on pesticides.  This is the original Red Dragon® Torch Kit and continues to be the most popular torch kit in North America. This 500,000 BTU/hr torch is our most powerful vapor torch and can handle the toughest jobs all year long. A great overall utility torch for years and years of service. Perfect for Farm and Ranch, Construction, Road Crews, Grounds Maintenance, Industry and More. Runs on tank pressure. No regulator required. Torch has a 3″ diameter bell and a total length of 33 1/2″.

Please find additonal technical information here on the flame engineering website.

The kit above contains:

– 500.000 BTU Vapor Torch
-Adjustable Needle Valve

-Squeeze Valve with Adjustable Pilot & Handle
-Spark Lighter
-Gas Hose
-POL connection for standard Australian Gas Cylinder

This kit can be connected to a standard Australian Gas Cylinder!

Watch the Red Torch on Youtube in Action!

vt3-30c red weed burner in action burning weed

Check out our other weed burners: VT2-23C & VT2-23SVC with squeeze handle.

 

Customer question:

Hi thanks for the prompt mailing of the Red Dragon.
I am having trouble with the power of the flame.Having connected the needle valve and hose and flitted it to a newly filled 9Kg. cylinder (from Bunnings) I lit the burner.The flame burned with a soft yellow flame which did not effect the weeds at all.The cylinder was on a 2 wheel trolley and when I tilted it and the cylinder was on an angle the burner burned correctly, however after about 5 or 10 minutes the gas flow was restricted as the hose was very cold ( perhaps frozen).Can you please advise me on a solution.
Regards T.

Our answer:

Hi T.,

What will be happening is that the excess flow valve (that is located in the POL fitting at the regulator) is shutting.

This happens when the valve is turned on and the rush of gas slams the excess flow valve shut.

They are not 100% positive shut off. It  is designed this way so the pressure can equalise and the excess flow valve can re-open. This is why you have a small yellow flame (gas can still pass through the valve).

If you wait long enough the pressure will equalise or close the cylinder valve, wait a while and open the valve slowly and this should fix the problem.

The RRP includes GST.